Acta Oncol ; 63: 56-61, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38404218

RESUMO

BACKGROUND AND PURPOSE: Proton therapy for breast cancer is usually given in free breathing (FB). With the use of deep inspiration breath-hold (DIBH) technique, the location of the heart is displaced inferiorly, away from the internal mammary nodes and, thus, the dose to the heart can potentially be reduced. The aim of this study was to explore the potential benefit of proton therapy in DIBH compared to FB for highly selected patients to reduce exposure of the heart and other organs at risk. We aimed at creating proton plans with delivery times feasible with treatment in DIBH. MATERIAL AND METHODS: Sixteen patients with left-sided breast cancer receiving loco-regional proton therapy were included. The FB and DIBH plans were created for each patient using spot-scanning proton therapy with 2-3 fields, robust and single field optimization. For the DIBH plans, minimum monitor unit per spot and spot spacing were increased to reduce treatment delivery time. RESULTS: All plans complied with target coverage constraints. The median mean heart dose was statistically significant reduced from 1.1 to 0.6 Gy relative biological effectiveness (RBE) by applying DIBH. No statistical significant difference was seen for mean dose and V17Gy RBE to the ipsilateral lung. The median treatment delivery time for the DIBH plans was reduced by 27% compared to the FB plans without compromising the plan quality. INTERPRETATION: The median absolute reduction in dose to the heart was limited. Proton treatment in DIBH may only be relevant for a subset of these patients with the largest reduction in heart exposure.


Assuntos
Neoplasias da Mama , Terapia com Prótons , Lesões por Radiação , Neoplasias Unilaterais da Mama , Humanos , Feminino , Neoplasias da Mama/radioterapia , Prótons , Dosagem Radioterapêutica , Suspensão da Respiração , Planejamento da Radioterapia Assistida por Computador/métodos , Coração , Neoplasias Unilaterais da Mama/radioterapia , Órgãos em Risco
2.
Colorectal Dis ; 25(3): 458-488, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35969031

RESUMO

AIM: Colorectal cancer survivors are one of the most rapidly growing groups of patients living with and beyond cancer. In a national multidisciplinary setting, we have examined the extent of late treatment-related sequelae in colorectal cancer survivors and present the scientific evidence for management of these conditions in this patient category with the aim of facilitating identification and treatment. METHOD: A systematic search for existing guidelines and relevant studies was performed across 16 and 4 databases, respectively, from inception to 2021. This yielded 13 guidelines and 886 abstracts, of which 188 were included in the finalized guideline (231 included for full text review). Secondarily, bibliographies were cross-referenced and 53 additional articles were included. RESULTS: Symptoms have been divided into overall categories including psychosocial, bowel-related, urinary, sexual (male and female), pain/neuropathy and fatigue symptoms or complaints that are examined individually. Merging and grading of data resulted in 22 recommendations and 42 management strategies across categories. Recommendations are of a more general character, whereas management strategies provide more practical advice suited for initiation on site before referral to specialized units. CONCLUSION: Treatment-related sequelae in colorectal cancer survivors are common and attention needs to be focused on identifying patients with unmet treatment needs and the development of evidence-based treatment algorithms.


Assuntos
Sobreviventes de Câncer , Neoplasias Colorretais , Feminino , Humanos , Masculino , Sobreviventes de Câncer/psicologia , Neoplasias Colorretais/complicações , Neoplasias Colorretais/terapia , Neoplasias Colorretais/psicologia , Dor
3.
Phys Imaging Radiat Oncol ; 21: 66-71, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35243034

RESUMO

BACKGROUND AND PURPOSE: Cardiac implantable electronic device (CIED) malfunctions can be induced by secondary neutron dose from spot-scanning proton therapy. A recent in-vitro study investigating secondary neutron dose to CIEDs up to 7 mSv per fraction found that exposure of secondary neutrons in this range was clinically manageable. This study presents decision algorithms proposed by a national expert group for selection of patients with breast and head & neck (H&N) cancer with CIEDs adjacent to target for proton therapy based on the 7 mSv threshold. METHODS AND MATERIALS: Ten patients with breast cancer and five with H&N cancer were included in the study. Five patients with breast cancer received photon therapy with CIED and proton plans were retrospectively created. The remaining patients received proton therapy without CIED and a worst-case position of a virtual CIED was retrospectively delineated. Secondary neutron dose was estimated as ambient dose equivalent H*(10) using Monte Carlo simulations. RESULTS: For patients with breast cancer and with contralateral CIED, the secondary neutron dose to the CIED was below 7 mSv per fraction for CTV < 1500 cm3 in 2 Gy fractions and CTV < 1000 cm3 in 2.67 Gy fractions. The secondary neutron dose to the CIED was below 7 mSv per fraction for all patients with H&N cancer. CONCLUSIONS: Simulations of neutron exposure suggest that proton therapy is feasible for most patients with CIED adjacent to target. This forms the basis for decision algorithms for selection of patients with CIED for proton therapy.

5.
Acta Oncol ; 61(2): 223-230, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34632922

RESUMO

BACKGROUND: The Danish Breast Cancer Group (DBCG) Proton Trial randomizes breast cancer patients selected on high mean heart dose (MHD) or high lung dose (V20Gy/V17Gy) in the photon plan between photon and proton therapy. This study presents the proton plans and adaptation strategy for the first 43 breast cancer patients treated with protons in Denmark. MATERIAL AND METHODS: Forty-four proton plans (one patient with bilateral cancer) were included; 2 local and 42 loco-regional including internal mammary nodes (IMN). Nineteen patients had a mastectomy and 25 a lumpectomy. The prescribed dose was either 50 Gy in 25 fractions (n = 30) or 40 Gy in 15 fractions (n = 14) wherefrom five received simultaneous integrated boost to the tumor bed. Using 2-3 en face proton fields, single-field optimization, robust optimization and a 5 cm range shifter ensured robustness towards breathing motion, setup- and range uncertainties. An anatomical evaluation was performed by evaluating the dose after adding/removing 3 mm and 5 mm tissue to/from the body-outline and used to define treatment tolerances for anatomical changes. RESULTS: The nominal and robust criteria were met for all patients except two. The median MHD was 1.5 Gy (0.5-3.4 Gy, 50 Gy) and 1.1 Gy (0.0-1.5 Gy, 40 Gy). The anatomical evaluations showed how 5 mm shrinkage approximately doubled the MHD while 5 mm swelling reduced target coverage of the IMN below constraints. Ensuring 3-5 mm robustness toward swelling was prioritized but not always achieved by robust optimization alone emphasizing the need for a distal margin. Twenty-eight patients received plan adaptation, eight patients received two, and one received five. CONCLUSION: This proton planning strategy ensured robust treatment plans within a pre-defined level of acceptable anatomical changes that fulfilled the planning criteria for most of the patients and ensured low MHD.


Assuntos
Neoplasias da Mama , Terapia com Prótons , Radioterapia de Intensidade Modulada , Neoplasias da Mama/radioterapia , Feminino , Humanos , Mastectomia , Órgãos em Risco , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
6.
Int J Radiat Oncol Biol Phys ; 111(1): 186-195, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33845147

RESUMO

PURPOSE: Cardiac implantable electronic devices (CIED) are sensitive to scattered secondary neutrons from proton beam irradiation. This experimental in vitro study investigated risk of CIED errors during pencil beam proton therapy. METHODS AND MATERIALS: We used 62 explanted CIEDs from 4 manufacturers; 49 CIEDs were subjected to a simulated clinical protocol with daily 2 Gy relative biological effectiveness fractions prescribed to the phantom. Devices were located at 3 different lateral distances from the spread-out Bragg peak to investigate the risk of permanent or temporary device errors. Additionally, 13 devices with leads connected were monitored live during consecutive irradiations to investigate the risk of noise, over- or undersense, pace inhibition, and inappropriate shock therapy. RESULTS: We detected 61 reset errors in 1728 fractions, and all except 1 CIED were reprogrammed to normal function. All, except 1 reset, occurred in devices from the same manufacturer. These were successfully reprogrammed to normal function. The 1 remaining CIED was locked in permanent safety mode. Secondary neutron dose, as estimated by Monte Carlo simulations, was found to significantly increase the odds of CIED resets by 55% per mSv. Clinically significant battery depletion was observed in 5 devices. We observed no noise, over- or undersense, pace inhibition, or inappropriate shock therapy during 362 fractions of live monitoring. CONCLUSIONS: Reprogrammable CIED reset was the most commonly observed malfunction during proton therapy, and reset risk depended on secondary neutron exposure. The benefits of proton therapy are expected to outweigh the risk of CIED malfunctioning for most patients.


Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Terapia com Prótons/efeitos adversos , Falha de Equipamento , Humanos , Método de Monte Carlo , Nêutrons
7.
Pregnancy Hypertens ; 14: 9-14, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30527125

RESUMO

OBJECTIVES: This study compares differences in the long-term myocardial function between women with early (EOPE) and late onset preeclampsia (LOPE) and age matched normotensive controls using two-dimensional speckle tracking echocardiography. METHODS: The study population comprised 93 women who gave birth at Department of Gynecology and Obstetrics, Randers Regional Hospital between 1998 and 2008. The women were grouped as EOPE (n = 31), LOPE (n = 22), and women with previous normotensive pregnancies (n = 40). All women underwent comprehensive blinded echocardiographic assessment of myocardial function. RESULTS: The median time since delivery was 12 years [9;15]. Left ventricular (LV) ejection fraction did not differ between groups. In contrast, LV longitudinal systolic myocardial function by LV global longitudinal strain (LVGLS) magnitude was significantly lower in EOPE women than controls (-18 ±â€¯3% versus -21 ±â€¯2%, p < 0.001) and LOPE women (-18 ±â€¯3% versus -21 ±â€¯2%, p < 0.01). In alignment with systolic parameters, the diastolic filling pattern indicated more restrictive filling pattern in EOPE women than controls and LOPE women. Thus, EOPE women had lower septal e' velocities leading to lower mean e' and subsequently higher E/e' ratio (p < 0.01) than controls and LOPE women. LVGLS was the echocardiographic parameter with the strongest association with EOPE in ROC curves. CONCLUSIONS: Women with a history of EOPE are more likely to have subclinical impairment of left ventricular function 12 years after PE than are those with a history of LOPE and controls. LVGLS was the echocardiographic parameter with the strongest association with EOPE.


Assuntos
Pré-Eclâmpsia , Cuidado Pré-Natal , Transtornos Puerperais/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Adulto , Estudos de Casos e Controles , Ecocardiografia , Feminino , Seguimentos , Humanos , Gravidez , Sistema de Registros , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS